Product Information
ERP DATA
Applicable ErP energy efficiency labels are supplied with each of the products. A separate ErP product fiche document is provided with the Logic Air Heat Pump. If a Logic Air Cylinder product is installed, refer to Table 2 to Table 4 within this document for the cylinder product fiche.
Table 1 Data – Heat Pump
| Description | Unit | 4kW Logic Air | 5kW Logic Air | 8kW Logic Air | 10kW Logic Air |
|---|---|---|---|---|---|
| Physical Properties | |||||
| Packaged Weight – Gross (Unpackaged Weight (Net)) | kg | 96 (86) | 96 (86) | 123 (110) | 123 (110) |
| Height (Unpackaged) | mm | 980 (798) | 980 (798) | 1190 (1008) | 1190 (1008) |
| Width (Unpackaged) | mm | 1175 (1095) | 1175 (1095) | 1175 (1095) | 1175 (1095) |
| Depth (Unpackaged) | mm | 600 (521) | 600 (521) | 600 (518) | 600 (518) |
| Performance Data | |||||
| Coefficient of Performance (A+7 at W35 / W55) | COP | 5.34 / 3.00 | 5.15 / 3.04 | 5.19 / 3.05 | 4.88 / 2.98 |
| Coefficient of Performance (A-7 at W35 / W55) | COP | 3.21 / 2.01 | 3.13 / 2.13 | 3.19 / 2.14 | 3.12 / 2.14 |
| Seasonal Coefficient of Performance (W35 / W55) | SCOP | 4.96 / 3.48 | 5.07 / 3.65 | 5.16 / 3.70 | 5.19 / 3.73 |
| Sound Power Level * | dB (A) | 52 | 52 | 55 | 55 |
| Sound Pressure Level @ 1m / 3m / 5m | dB (A) | 44 / 34.5 / 30 | 44 / 34.5 / 30 | 47 / 37.5 / 33 | 47 / 37.5 / 33 |
| Maximum Outdoor Temperature | °C | 35 | 35 | 35 | 35 |
| Minimum Outdoor Temperature | °C | -20 | -20 | -20 | -20 |
| Heat Output | |||||
| A+7°C/W+35°C | kW | 4.0 | 5.0 | 8.0 | 10 |
| A+7°C/W+55°C | kW | 4.0 | 5.0 | 8.0 | 10.0 |
| A-7°C/W+35°C | kW | 4.1 | 5.1 | 8.2 | 9.53 |
| A-7°C/W+55°C | kW | 3.7 | 4.8 | 7.5 | 8.5 |
| Electrical Properties | |||||
| Electrical Supply Requirements | |||||
| Rated Supply Voltage | V | 230 | 230 | 230 | 230 |
| Frequency | Hz | 50 | 50 | 50 | 50 |
| No. of Supply Phases | – | Single | Single | Single | Single |
| Maximum Current | A | 12 | 12 | 22 | 22 |
| Fuse Rating | A | 16 | 16 | 32 | 32 |
| Outdoor Unit Properties | |||||
| IP Rating | – | X4 | X4 | X4 | X4 |
| Compressor Control Type | – | Inverter | Inverter | Inverter | Inverter |
| Electrical Power Consumption | |||||
| A+7°C/W+35°C | kW | 0.75 | 0.97 | 1.54 | 2.05 |
| A+7°C/W+55°C | kW | 1.33 | 1.64 | 2.62 | 3.36 |
| A-7°C/W+35°C | kW | 1.28 | 1.63 | 2.56 | 3.05 |
| A-7°C/W+55°C | kW | 1.84 | 2.25 | 3.50 | 3.97 |
| Heating Circuit Requirements | |||||
| Hydronic Connections | – | 1″ BSP Male | 1″ BSP Male | 1″ BSP Male | 1″ BSP Male |
| Maximum Operating Pressure | bar | 3 | 3 | 3 | 3 |
| Minimum Flow Rate of the Hydronic Circuit | l/min | 8.5 | 8.5 | 14.5 | 14.5 |
| Maximum Flow Temperature | °C | 60 | 60 | 60 | 60 |
| Minimum Operating Water Temperature (without pre-heating) | °C | 17 | 17 | 17 | 17 |
| Minimum Primary System Volume | L | Refer to Primary Heating System Requirements | Refer to Primary Heating System Requirements | Refer to Primary Heating System Requirements | Refer to Primary Heating System Requirements |
| Hydraulic Resistance | – | Refer to Pump Curves | Refer to Pump Curves | Refer to Pump Curves | Refer to Pump Curves |
| Refrigerant Data | |||||
| Refrigerant | – | R32 | R32 | R32 | R32 |
| Factory Refrigerant Charge | grams | 880 | 880 | 1,470 | 1,470 |
| GWP Rating | – | 675 | 675 | 675 | 675 |
| ODL Rating | – | 0 | 0 | 0 | 0 |
| Flammability Rating | – | A2L | A2L | A2L | A2L |
| Maximum Circuit Pressure | bar | 42 | 42 | 42 | 42 |
| Compressor Type | – | Twin Rotary | Twin Rotary | Twin Rotary | Twin Rotary |
| Compressor Oil | – | RmM68 Alkylbenzene | RmM68 Alkylbenzene | RmM68 Alkylbenzene | RmM68 Alkylbenzene |
- Tested in accordance with EN 12102-1 Annex A